INPUT DATA

Number of MPP trackers

2,0

Max. input current (Idc max)

18 / 18 A

Max. short circuit current, module array

27 / 27 A

DC input voltage range (Udc min - Udc max)

80 - 1000 V

Feed-in start voltage (Udc start)

80,0 V

Nominal input voltage (Udc,r)

710,0 V

MPP voltage range (Umpp min - Umpp max)

240 - 800 V
Usable MPP voltage range 80 - 800 V
Number of DC connections 2 + 2

Max. PV generator power (Pdc max) 

7,5 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)

4600,0 W

Max. output power (Pac max)

5000,0 VA

AC output current (Iac nom)

21,7 A

Grid connection (Uac,r)

1~ NPE 220/230 V

AC voltage range (Umin - Umax)

180 - 270 V

Frequency (fr)

50 / 60 Hz

Frequency range (fmin - fmax)

45 - 65 Hz

Total harmonic distortion

< 5 %

Power factor (cos φac,r)

0,85 - 1 ind./cap.

GENERAL DATA

Height 645,0 mm
Width 431,0 mm
Depth 204,0 mm
Weight 21,5 kg
Degree of protection IP 65
Protection class 1,0

Overvoltage category (DC / AC) 1)

2 / 3
Night-time consumption < 1 W
Inverter design Transformerless
Cooling Regulated air cooling
Installation Indoors and outdoors
Ambient temperature range -40°C - +55°C
Permitted humidity 0 - 100 %

Max. altitude 2)

4.000 m
DC connection technology 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm²
AC connection technology 3-pin AC screw terminals 2.5 - 16 mm²
Certificates and compliance with standards DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,<br /> AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105

EFFICIENCY

Max. efficiency (PV - grid) 98,1 %
European efficiency (ηEU) 97,1 %

η at 5% Pac,r 3)

80,8 / 82,5 / 82,5 %

η at 10% Pac,r 3)

89,6 / 94,8 / 93,1 %

η at 20% Pac,r 3)

93,4 / 97,2 / 96,2 %

η at 25% Pac,r 3)

94,1 / 97,3 / 96,8 %

η at 30% Pac,r 3)

94,7 / 97,4 / 97,0 %

η at 50% Pac,r 3)

95,8 / 97,9 / 97,7 %

η at 75% Pac,r 3)

96,1 / 98,0 / 97,9 %

η at 100% Pac,r 3)

96,2 / 97,9 / 97,9 %
MPP adaptation efficiency > 99,9 %

PROTECTION DEVICES

DC insulation measurement Yes
Overload behaviour Operating point shift, power limitation
DC disconnector Yes
Reverse polarity protection Yes

INTERFACES

WLAN / Ethernet LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs Interface to ripple control receiver

USB (type A socket) 4)

Data logging, inverter update via USB flash drive

2x RS422 (RJ45 socket) 4)

Fronius Solar Net

Signalling output 4)

Energy management (floating relay output)
Datalogger and web server Integrated

External input 4)

S0 meter connection / Evaluation of overvoltage protection
RS485 Modbus RTU SunSpec or meter connection

 